| Search | Login/Register
   Home » Analog Playback» Active Tonearm Monitoring System. (3 posts, 1 page)
  Print Thread | 1st Post |  
Page 1 of 1 (3 items) Select Pages: 
   Target    Threads for related reading   Most recent post in related threads   Forum  Replies   Views   Started 
  »  New  3012, 312, M2-12 or ... ?..  A closure....  Analog Playback Forum     1  24388  10-17-2008
  »  New  Micro Seiki MAX 282 User Manual..  Micro Seiki MAX 282 User Manual...  Analog Playback Forum     0  31730  03-16-2005
  »  New  SME M2-12 tonearm..  M2-12R specs...  Analog Playback Forum     10  154048  07-26-2004
  »  New  What is the difference between the cartridges?..  Some more links about Dynavector cartridges...  Analog Playback Forum     6  75367  09-12-2004
  »  New  Here is my new tonearm...  Korvet TT in German...  Analog Playback Forum     9  163583  12-11-2004
  »  New  Ultimate Turntable..  Techdas Designer Hideaki Nishikawa R.I.P...  Analog Playback Forum     220  1346639  05-31-2004
  »  New  The HoroMusic turnable...  And the 27" long tonearm might be a Moronic as thi...  Analog Playback Forum     6  68203  08-05-2009
  »  New  The 'Side's End Ceremony' or a need for a Smart Tonearm..  The 'Side's End Ceremony' or a need for a Smart Tonearm...  Analog Playback Forum     0  14986  11-05-2009
  »  New  A turntable platter as a turbine?..  A turntable platter as a turbine?...  Analog Playback Forum     0  16859  10-27-2010
07-14-2009 Post mapped to one branch of Knowledge Tree
Romy the Cat


Boston, MA
Posts 10,184
Joined on 05-28-2004

Post #: 1
Post ID: 11061
Reply to: 11061
Active Tonearm Monitoring System.
fiogf49gjkf0d

It possible that those systems exist but I never heard about them and even I think it is too late to invent the thing for record playing but I still do like the idea.

Pretend a needle reads grooves. Depth and the right-left variation of the groove are variable and the needle, cantilever and attached coil change their position in space generating voltage. However, the movable part of the groove-reading mechanism experiences also the inertia that comes from its mass and speed. That inertia gets propagated to tonearm and to a very small degree tonearm itself behaves like a needle. The magnitude of this effect varies depend of the different criteria – I will not go into details now. Then there is the problem with record that creates very large tracing errors. The warped record dynamically changes VTF very aggressively and a record with off-center hole dynamically changes antiscating force. Those vertical and horizontal macro-disturbances added to the needle-cantilever-coil inertia create variable pressure of needle to groove, is any ways to deal with it?

I remember in my army time I drove a tank a few times and that tank has a system that was called “Duck”. It was called after duck (the bird) that is able to walk and to wave its bid ass but the duck’s head is able to maintain a more or less stable position. So, that tank had active electro-mechanical cannon’s axis stabilization system that allowed the tank to drive over erratic terrain but to maintain the main gun’s aim unchanged. Alternatively take a look what Kinetic Systems do.

http://www.kineticsystems.com/page156.html

It is an Active Feedback Vibration Control system that injects contra-force if detects any vibration. Combine what Kinetic Systems de with the “Duck” system and we will come close to what I am proposing. Approximately 5-6 years ago I proposed a conceptual idea of a tonearm with damping decoupled gyroscope on other end where each characteristic of tonearms would be managed just buy a precise positioning of set of gyroscopes. Let combine all of this together and see what we might come up with.

Pretend that we have a tonearm with a normal mechanical or liquid dumping and so on. The back of the tonearm has no weighs and has two independent electromagnetic sections. The first section surrounded with 3-4 electromagnets (on all sides). This is “write section” by means of witch the tonearm brain magnetizes the 3-4 electromagnets and inflicts to tonearm the VTF, antiscating, and also any transient vertical and horizontal anti-vibration and error-correction forces. The second section surrounded with 3-4 coils. This is “read section” that indicate to tonearm brain the exact position of tonearm in relation to the magnetizing forces of the first section. The tonearm brain is a piece of analog or digital logic that process all data, accept the preset defaults and generates an operational pattern for the whole tonearm.

The whole point of this idea is that the concept might provide absolutely problem-free LP reading disregarding any conditions – you can run you TT even upside down, not mention that it might easy do proper automated record playing, finding the beginning of record.

ActiveTonearmMonitoringSystem.JPG

I did not see people go into this direction this type of tonearm VERY essay to do. With one more electromagnet on the tonearm base it would be very easy to do even automated VTA self-abasement. The “tonearm brain” might read an input from the phonostage and paling a calibration record with test signals it might recalibrate itself and to save for a given cartridge the setting of the best objective operational parameters. It might even recommend the best effective mass for a given cartridge that might be very easily to be re-set by adding mass to the headshell. The opportunities with this idea of Active Tonearm Monitoring System are truly endless…

Rsg, Romy the Cat


"I wish I could score everything for horns." - Richard Wagner. "Our writing equipment takes part in the forming of our thoughts." - Friedrich Nietzsche
07-14-2009 Post does not mapped to Knowledge Tree
Paul S
San Diego, California, USA
Posts 2,672
Joined on 10-12-2006

Post #: 2
Post ID: 11066
Reply to: 11061
Of An Ilk?
fiogf49gjkf0d
As far as I know the Schroder arms do not generate electricity like that.  But they do use magnets for one end of their suspension and they are said to generate what Herr Schroder refers to as (quasi-electro-mechanical?) magnetic "eddy currents", which are said to generate forces contra to the activating forces.

It may not be obvious to Schroder's shoppers at first, but perhaps it is no surprise that the most effective magnets are more expensive, not only because they are more powerful but also because they are specially ground to maintain equinamity when tracking warps, etc.  The sub-optimal models have effects - including VTF - that vary when tracking warps.

The best fluid damping is designed per arm, with effects that vary according to the particular arm's resonance.  Also, one should be able to tune it, per cartridge.  Among other things, it should discriminate between LF resonance and warp and wow, adequately damping the former and only stopping inertia with the latter two conditions.

Is it ironic that Romy's feedback scheme looks like a sort of uber-cartridge?

Paul s
10-08-2009 Post does not mapped to Knowledge Tree
Romy the Cat


Boston, MA
Posts 10,184
Joined on 05-28-2004

Post #: 3
Post ID: 11926
Reply to: 11061
The most idiotic idea I’ve ever seen
fiogf49gjkf0d
Ok, I made a very rudimental prototype of the “Active Tonearm Monitoring System” that I described above. What can I say? I cannot believe how much Moran I was even proposing it!  The Active Tonearm Monitoring System “works” perfectly fine but there is a minor “glitch”.  The electromagnets induce in the cores some perfectly expectable vibrations and the core of the electromagnets is the wand of the tonearm. I can’t even describe how hard I was laughing on myself when I powered my prototype on. It was beyond ridicules!

The Cat


"I wish I could score everything for horns." - Richard Wagner. "Our writing equipment takes part in the forming of our thoughts." - Friedrich Nietzsche
Page 1 of 1 (3 items) Select Pages: 
   Target    Threads for related reading   Most recent post in related threads   Forum  Replies   Views   Started 
  »  New  3012, 312, M2-12 or ... ?..  A closure....  Analog Playback Forum     1  24388  10-17-2008
  »  New  Micro Seiki MAX 282 User Manual..  Micro Seiki MAX 282 User Manual...  Analog Playback Forum     0  31730  03-16-2005
  »  New  SME M2-12 tonearm..  M2-12R specs...  Analog Playback Forum     10  154048  07-26-2004
  »  New  What is the difference between the cartridges?..  Some more links about Dynavector cartridges...  Analog Playback Forum     6  75367  09-12-2004
  »  New  Here is my new tonearm...  Korvet TT in German...  Analog Playback Forum     9  163583  12-11-2004
  »  New  Ultimate Turntable..  Techdas Designer Hideaki Nishikawa R.I.P...  Analog Playback Forum     220  1346639  05-31-2004
  »  New  The HoroMusic turnable...  And the 27" long tonearm might be a Moronic as thi...  Analog Playback Forum     6  68203  08-05-2009
  »  New  The 'Side's End Ceremony' or a need for a Smart Tonearm..  The 'Side's End Ceremony' or a need for a Smart Tonearm...  Analog Playback Forum     0  14986  11-05-2009
  »  New  A turntable platter as a turbine?..  A turntable platter as a turbine?...  Analog Playback Forum     0  16859  10-27-2010
Home Page  |  Last 24Hours  | Search  |  SiteMap  | Questions or Problems | Copyright Note
The content of all messages within the Forums Copyright © by authors of the posts