Post Subject: Power sequencing?Posted by N-set on: 10/4/2012
fiogf49gjkf0d
I have one problem, probably trivial: when I shut the power off, the HV dies out much longer than the filaments,
so the cathodes are poisoned at the switch off (on the startup I have a delay relay on HV).
And this despite all that heavy bleeding on HV. How do you deal with such things?