Rerurn to Romy the Cat's Site


In the Forum: Didital Things
In the Thread: Pacific Microsonics Model 2
Post Subject: Weiss AFI1 does not conform to dual-wire standardPosted by manisandher on: 9/29/2009
fiogf49gjkf0d
 Romy the Cat wrote:
Lynx has internal dabbler that activated as soon dual-wire inputs activated. So, when Pacific outputs in dual-wire configuration a half of the sampling speed then is done in accordance to the dual-wire specification.

This makes a lot of sense. (Incidentally, my Esoteric D70 in dual-wire mode does exactly the same as the Pacific.)

But I'm really cheesed off that my Weiss AFI1 does not conform with the dual-wire standard. It should be doubling the clock frequency, as the Lynx does. I will insist that Daniel Weiss gives me an explanation of why it doesn't... and what he is going to do about it.

Mani.